Standard Cylinder :

The Theoretical output of the cylinder is the product of cross-sectional area of piston on which the compressor air applied, and Air pressure supplied to it.

Reed switches are to be ordered separately. Reed switches are required / used in Cylinders with Magnetic Piston

Normally our cylinders will withstand 60 degree Celsius, Our cylinders with Viton seal withstand 150-degree Celsius. Viton Seal Cylinders are to be specified during order.

Using Flow control valves.

You can use a 5 port, 3 position valve which has a closed centre position. This will stop the cylinder in a mid-position however the positional accuracy of using this method is not good. And Other method is using proportional regulators / valves to control cylinder stroke with respect to input signals.

For getting the equivalent cylinder Bore diameter and Stroke length are important one, knowing that we shall easily select the cylinder from our website. However, based on Type of operation, Size, Model, duty, conformity to standards, materials of construction, working ambient temperature, etc., are also to be considered. If you have any doubts, kindly write to us. we will be happy to advise you the most suitable equivalent for your application.

YES, Our Cylinders conforming to ISO/VDMA standards are interchangeable with other cylinders those are also conforms to standards

320mm dia cylinder. However please contact us.

They have a power stroke in one direction only with a spring, gravity or other external force to return the rod.

Yes, Cylinders shall be positioned upside down